| PLANS RECEIVED | 4/29/2026 | CHELSEY GONZALES |
(4/29/2026 10:13 AM CGO)
Hi Priscilla,
I heard back from Symons and was able to close out their permit. Your permit number is FIRE26-0104 and the expected due date is 5/11/26.
I should have caught this when the plans were first submitted, but I was focused on sorting out the duplicate fire alarm plans. While reviewing your submittal, I noticed that the fire alarm system does not meet our mid-rise ordinance requirements for voice evacuation and smoke detection in the corridors. Please refer to the City of Oceanside Municipal Code here: Sec. 11.19. - Mid-rise buildings. | Code of Ordinances | Oceanside, CA | Municode Library.
You have the option to resubmit revised plans by 5/6; otherwise, we will proceed with reviewing the current set. We anticipate completing the review at the end of next week, likely on 5/7 or 5/8. If you plan to submit updated plans but do not expect to meet the 5/6 deadline, please let me know so I can inform the plans examiner and push the review back a few days.
Thank you,
Chelsey Gonzales
Permit Technician II
City of Oceanside
Oceanside Fire Department
cgonzales@oceansideca.org
+1 (760) 435-4318
300 N. Coast Highway
Oceanside, CA 92054
fire.ci.oceanside.ca.us
From: Priscilla Figueroa
Sent: Wednesday, April 22, 2026 9:35 AM
To: OFD Plan Submittal
Cc: Vanessa Montoya ; Mike Bennett
Subject: Re: 1111 S Coast Hwy Fire Alarm System
Good morning Chelsey,
Following up on the previous confusion regarding the designated fire alarm contractor, we would like to confirm that our submittal is the only active fire alarm permit under review for 1111 S Coast Hwy in Oceanside, 92054.
We have since confirmed with our client that Symons Fire Protection also submitted a fire alarm plan set. Based on this, could you please confirm that there are no duplicate or conflicting fire alarm permits currently in process, and that our plans will be the set moving forward for review?
Please let us know if you need any additional information from our end.
Thank you,
Priscilla Figueroa
Systems Designer
HCI Systems Inc.
4585 Murphy Canyon Road, San Diego, CA 92123
C: (858) 560-7000- Ex. 1403 | F: (858) 560-7007
E: pfigueroa@hcisystems.net
From: OFD Plan Submittal
Sent: Tuesday, April 21, 2026 5:04 PM
To: Priscilla Figueroa
Cc: Vanessa Montoya ; Mike Bennett
Subject: RE: 1111 S Coast Hwy Fire Alarm System
Perfect, thank you!
I will send you a confirmation email with the permit number tomorrow once I check in the plans.
Thank you,
Chelsey Gonzales
Permit Technician II
City of Oceanside
Oceanside Fire Department
cgonzales@oceansideca.org
+1 (760) 435-4318
300 N. Coast Highway
Oceanside, CA 92054
fire.ci.oceanside.ca.us
From: Priscilla Figueroa
Sent: Tuesday, April 21, 2026 11:22 AM
To: OFD Plan Submittal
Cc: Vanessa Montoya ; Mike Bennett
Subject: Re: 1111 S Coast Hwy Fire Alarm System
Hi Chelsey,
Please see the email attached from the GC confirming that HCI is the designated fire alarm contractor for this project. Please let us know if you need anything further.
Thank you,
Priscilla Figueroa
Systems Designer
HCI Systems Inc.
4585 Murphy Canyon Road, San Diego, CA 92123
C: (858) 560-7000- Ex. 1403 | F: (858) 560-7007
E: pfigueroa@hcisystems.net
________________________________________
From: OFD Plan Submittal
Sent: Tuesday, April 21, 2026 8:54 AM
To: San Diego Engineering Dept 403 <403ENGINEERING@HCISYSTEMS.NET>
Subject: 1111 S Coast Hwy Fire Alarm System
Hello,
I’mreaching out regarding the fire alarm plan submittal for 1111 S Coast Hwyin Oceanside, 92054. I have already received a set of fire alarm plan from Symons Fire Protection on 4/15/26.
Before I can proceed with checking in these plans, I will need confirmation from the general contractor regarding the designated fire alarm contractor for this project.
Thank you,
Chelsey Gonzales
Permit Technician II
City of Oceanside
Oceanside Fire Department
cgonzales@oceansideca.org
+1 (760) 435-4318
300 N. Coast Highway
Oceanside, CA 92054
fire.ci.oceanside.ca.us |